Search results for "Iodinated contrast"

showing 4 items of 4 documents

Gadolinium-DTPA (Magnevist®) als Kontrastmittel für die arterielle DSA

1994

16 DSA investigations using intra-arterial Gd-DTPA were performed on 12 patients. The contrast medium was administered either as a 0.5 molar gadolinium solution (commercially available) or diluted with distilled water to a 0.2-0.4 molar gadolinium solution. The injection was made either by pressure injector or by hand. The aortic arch, abdominal aorta and pelvic and lower limb arteries were examined. 14 of the 16 procedures were diagnostically adequate, but compared with iodinated contrast materials, contrast was less marked. There were no cardiovascular, neurological or allergic side effects. Three patients suffered a feeling of heat and one patient had mild pain during the injection. Even…

Aortic archMolarmedicine.medical_specialtymedicine.diagnostic_testbusiness.industryGadoliniumAbdominal aortachemistry.chemical_elementIopamidolContrast mediumIodinated contrastchemistrymedicine.arteryAngiographymedicineRadiology Nuclear Medicine and imagingRadiologybusinessNuclear medicinemedicine.drugRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Comparison of iodinated contrast media for the assessment of atherosclerotic plaque attenuation values by CT coronary angiography: observations in an…

2013

Objective: To compare the influence of different iodinated contrast media with several dilutions on plaque attenuation in an ex vivo coronary model studied by multislice CT coronary angiography. Methods: In six ex vivo left anterior descending coronary arteries immersed in oil, CT (slices/collimation 64x0.625 mm, temporal resolution 210 ms, pitch 0.2) was performed after intracoronary injection of a saline solution, and solutions of a dimeric isosmolar contrast medium (Iodixanol 320 mgl ml(-1)) and a monomeric high-iodinated contrast medium (Iomeprol 400 mgl ml(-1)) with dilutions of 1/80 (low concentration), 1/50 (medium concentration), 1/40 (high concentration) and 1/20 (very high concent…

Malemedicine.medical_specialtySerial dilutionmedicine.medical_treatmentContrast MediaCoronary Artery Diseaseatherosclerotic plaqueIn Vitro TechniquesCoronary AngiographySensitivity and SpecificityIopamidolCoronary artery diseaseCT Coronary AngiographyTriiodobenzoic AcidsMedicineHumansRadiology Nuclear Medicine and imagingSalineFull PaperDose-Response Relationship Drugex-vivo modelbusiness.industryAttenuationReproducibility of ResultsGeneral MedicineMiddle Agedmedicine.diseaseIopamidolCoronary arteriesContrast mediummedicine.anatomical_structureIodinated contrast mediaFemaleRadiologySettore MED/36 - Diagnostica Per Immagini E RadioterapiabusinessTomography X-Ray ComputedEx vivomedicine.drug
researchProduct

Diagnostic accuracy of 64-slice CT in the assessment of coronary stents

2007

PURPOSE: The purpose of this study was to assess the diagnostic accuracy of 64-slice computed tomography (64-CT) coronary angiography in the detection of coronary in-stent restenosis. MATERIALS AND METHODS: Ninety-five patients (72 men and 23 women, mean age 58+/-8 years) with previous percutaneous coronary intervention with stenting and suspected restenosis underwent 64-CT (Sensation 64, Siemens). The mean time between stent deployment and 64-CT was 6.1+/-4.2 months. The scan parameters were: slices 32 x 2, individual detector width 0.6 mm, rotation time 0.33 s, feed 3.84 mm/rotation, 120 kV, 900 mAs. After the intravenous administration of iodinated contrast material (Iomeprol 400 mgI/ml,…

Malemedicine.medical_specialtymedicine.medical_treatmentCoronary AngiographyCoronary RestenosisRestenosisIodinated contrastcoronary stentsHumansMedicineRadiology Nuclear Medicine and imagingSalineNeuroradiologymedicine.diagnostic_testbusiness.industryUltrasoundReproducibility of ResultsPercutaneous coronary interventionInterventional radiologyGeneral MedicineMiddle Agedmedicine.diseaseFemaleStentsRadiologyBolus (digestion)Tomography X-Ray ComputedbusinessRadiologia Medica
researchProduct

Infarct characterization using CT

2017

Myocardial infarction (MI) is a major cause of death and disability worldwide. The incidence is not expected to diminish, despite better prevention, diagnosis and treatment, because of the ageing population in industrialized countries and unhealthy lifestyles in developing countries. Nowadays it is highly requested an imaging tool able to evaluate MI and viability. Technology improvements determined an expansion of clinical indications from coronary plaque evaluation to functional applications (perfusion, ischemia and viability after MI) integrating additional phases and information in the mainstream examination. Cardiac computed tomography (CCT) and cardiac MR (CMR) employ different contra…

medicine.medical_specialtycoronary arterieIschemiaReview Article030204 cardiovascular system & hematologyPharmacological stress030218 nuclear medicine & medical imagingIodinated contrast media03 medical and health sciences0302 clinical medicineImaging Toolcardiovascular diseasemedicineMyocardial infarctionmyocardial infarction (MI)Cause of deathbusiness.industrycomputed tomographymedicine.diseaseCoronary arteriesmedicine.anatomical_structureAtherosclerosiRadiologyCardiology and Cardiovascular MedicinebusinessSettore MED/36 - Diagnostica Per Immagini E RadioterapiaPerfusionCardiovascular Diagnosis and Therapy
researchProduct